PROLOK INSTALLATION





                                                                                                            JULY 2025










            8. The final panel will need to be
            cut to fit the remaining area. Cut
            panel 1” wider(Prolok rib height) than the

            remaining area and fold up 1” to match
            the Prolok ribs, and provide a bench for the
            gable trim to sit on.







            NON-VENTED RIDGE
            9a. Once panels are completed

            the next step is to install
            closure strips along the top
            of the panels. After closures
            are complete, install Z Bar

            in the 1.5” space left between
            the ridge and the panels.









            VENTED RIDGE
            9b. Once panels are completed

            the next step is to install
            profile vent clips, 1 per ft.
            Fasten the clip on the bottom
            only to start. Bend up the front
            of the clip to slide in the profile

            vent. Then fasten down the top
            of the clip. The top of the clip
            should line up with the top of

            the panel.